CO2 Incubator Binder C150

The STANDARD CO2 incubator

The BINDER C 150 is the fitting CO2 incubator for routine applications for cell cultivation: contamination-free thanks to 180 °C hot-air sterilization, this CO2 incubator is reliably pH-stable thanks to the drift-free FPI infrared measuring system. In addition, the BINDER C 150 distinguishes itself by its high temperature precision with excellent dynamics and eliminates the risk of condensation when storing tissue cultures - even in high humidity.

Advantages:

  • Hot air sterilization at 180 °C
  • Seamless, deep-drawn inner chamber made of stainless steel
  • Unique BINDER technology (patented air jacket system, etc.)

Feature

1) To 98% of the set value
2) The specified recovery times of the gas concentration in the inner chamber after the door was opened is based on a connection pressure of 2.0 bar.
All technical data are specified for units with standard equipment at an ambient temperature of 25 °C and a line voltage fluctuation of ±10%. The temperature data is determined in accordance to factory standard following DIN 12880, respecting the recommended wall clearances of 10% of the height, width and depth of the inner chamber. All figures are typical average values for series devices. We reserve the right to alter technical specifications at any time.

Spesification


C 150
Exterior dimensions

Width (mm)680

Height (incl. feet) (mm)820

Depth (mm)815

Plus door handle, I-triangle (mm)54

Plus connections (mm)60

Wall clearance, rear (mm)100

Wall clearance, side (mm)50
   
Interior dimensions

Width (mm)500

Height (mm)600

Depth (mm)500

Interior volume (l)150

Stainless steel shelf (number standard/max.)3 / 6

Dimensions of perforated shelves, width x depth (mm)491 x 442

Dimensions (external dimensions) shelves width x depth (mm)495 x 444

Weight (kg)95
   
Temperature data

Temperature range from 7 °C above ambient temperature to (°C)50

Temperature variation at 37 °C (± K)0,4

Temperature fluctuation (± K)0,1

Recovery time after door was opened for 30 sec. at 37 °C (min) 1)5
   
CO2 data

CO2 range (Vol.-% CO2)0-20

Setting accuracy (Vol.-% CO2)0,1

Recovery time after door was opened for 30 sec. 5 vol. % (min.) 1) 2)7

CO2 measurementIR

Connection hose nozzle for CO2 DN 6 for hose with internal diameter (mm)6
   
Humidity data

Humidity (±2 % RH)95
   
Electrical data

IP protection class acc. to EN 60529IP 20

Voltage (± 10%) 50/60 Hz (V)230

Nominal power (kW)1,4

Energy consumption at 37 °C (W) 2)110